| Sign In | Join Free | My xxjcy.com |
|
Delivery Time : 15-19 working days
Stock : 15
Brand Name : EATON
Model Number : 16370-2
Packaging Details : -
MOQ : 1
Description : Power Distribution RoHS
High-quality power distribution and terminal blocks designed for reliable electrical connections. Featuring robust construction and multiple configuration options, these blocks are suitable for various industrial and commercial applications requiring efficient power management and distribution.
| Series | Type | Poles | Line/Load Wire Range (Cu/Al) | Ampacity (Al) | Stud Size | Notes |
| 16021 | Power Distribution | 2, 3, 4 | Line: 2/0 - #14Cu/#8Al; Load: #4 - #14Cu/#8Al | 175A | N/A | 6 Load openings per section |
| 16023 | Power Distribution | 2, 3, 4 | Line: 350MCM - #6Cu-Al; Load: #6 - #14Cu/#12Al | 310A | N/A | 6 Load openings per section |
| 16220 | Power Distribution | 1, 2, 3 | Line: 2/0 - #14Cu/#8Al; Load: #4 - #14Cu/#8Al | 175A | N/A | 4 Load openings per section |
| 16321 | Power Distribution | 1, 2, 3 | Line: 2/0 - #14Cu-Al; Load: #3 - #14Cu/#8Al | 175A | N/A | 6 Load openings per section |
| 16323 | Power Distribution | 1, 2, 3 | Line: 350MCM - #6Cu-Al; Load: #4 - #14Cu/#12Al | 310A | N/A | 6 Load openings per section |
| 16325 | Power Distribution | 1, 2, 3 | Line: (2) 2/0 - #14Cu, 2/0 - #8Al; Load: #4 - #14Cu/#12Al | 350A | N/A | 6 Load openings per section |
| 16327 | Power Distribution | 1, 2, 3 | Line: 500MCM - #2Cu-Al; Load: #4 - #14Cu/#12Al | 380A | N/A | 6 Load openings per section |
| 16330 | Power Distribution | 1, 2, 3 | Line: 500MCM - #6Cu-Al; Load: #2 - #14Cu/#8Al | 380A | N/A | 6 Load openings per section |
| 16332 | Power Distribution | 1, 2, 3 | Line: 350MCM - #6Cu-Al (3); Load: #2 - #14Cu/#8Al (2) 1/0 - #14Cu/#8Al | 310A | N/A | 2 Load openings per section |
| 16335 | Power Distribution | 1, 2, 3 | Line: 500MCM - #2Cu-Al (3); Load: #2 - #14Cu/#8Al (2) #1/0 - #14Cu/#8Al | 380A | N/A | 2 Load openings per section |
| 16370 | Power Distribution | 1, 2, 3 | Line: 350MCM - #6Cu-Al (12); Load: #4 - #14Cu/#8Al | 310A | N/A | 12 Line openings |
| 16371 | Power Distribution | 1, 2, 3 | Line: 350MCM - #6Cu-Al (6); Load: #2 - #14Cu/#8Al (3) 1/0 - #14Cu/#8Al | 310A | N/A | 6 Line openings |
| 16372 | Power Distribution | 1, 2, 3 | Line: 350MCM - #6Cu-Al (21); Load: #10 - #14Cu/#12Al | 310A | N/A | 21 Line openings |
| 16375 | Power Distribution | 1, 2, 3 | Line: 600MCM - #2Cu-Al (12); Load: #4 - #14Cu/#8Al | 420A | N/A | 12 Line openings |
| 16376 | Power Distribution | 1, 2, 3 | Line: 600MCM - #2Cu-Al (6); Load: #2 - #14Cu/#8Al (3) 1/0 - #14Cu/#8Al | 420A | N/A | 6 Line openings |
| 16528 | Power Distribution | 1, 2, 3 | Line: (2) 600MCM - #2Cu-Al (4); Load: 3/0 - #6Cu-Al (4) #4 - #14Cu, #4 - #12Al | 840A | N/A | 4 Load openings per section |
| 16530 | Power Distribution | 1, 2, 3 | Line: (2) 500MCM - #6Cu-Al (12); Load: #4 - #14Cu, #4 - #12Al | 760A | N/A | 12 Load openings per section |
| 16541 | Power Distribution | 1, 2, 3 | Line: 500MCM - #6Cu-Al (21); Load: #6 - #14Cu, #6 - #12Al | 380A | N/A | 21 Line openings |
| 16000 | Splicer Terminal | 2, 3, 4 | Line: 2/0 - #8Cu-Al; Load: 2/0 - #8Cu-Al | 175A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16003 | Splicer Terminal | 2, 3, 4 | Line: 250MCM - #6Cu; Load: 250MCM - #6Cu | 255A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16005 | Splicer Terminal | 2, 3, 4 | Line: 350MCM - #6Cu-Al; Load: 350MCM - #6Cu-Al | 310A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16200 | Splicer Terminal | 1, 2, 3 | Line: #2 - #14Cu, #2 - #8Al; Load: #2 - #14Cu, #2 - #8Al | 115A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16201 | Splicer Terminal | 1, 2, 3 | Line: 1/0 - #14Cu; Load: 1/0 - #14Cu | 150A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16204 | Splicer Terminal | 1, 2, 3 | Line: 2/0 - #8Cu-Al; Load: 2/0 - #8Cu-Al | 175A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16301 | Splicer Terminal | 1, 2, 3 | Line: 250MCM - #6Cu; Load: 250MCM - #6Cu | 255A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16303 | Splicer Terminal | 1, 2, 3 | Line: 350MCM - #6Cu-Al; Load: 350MCM - #6Cu-Al | 310A | N/A | 1 opening line-side, 1 opening load-side per phase |
| 16500 | Splicer Terminal | 1, 2, 3 | Line: (2) 350MCM - #4Cu-Al; Load: (2) 350MCM - #4Cu-Al | 620A | N/A | 2 openings line-side, 2 openings load-side per section |
| 16504 | Splicer Terminal | 1, 2, 3 | Line: (2) 500MCM - #6Cu-Al; Load: (2) 500MCM - #6Cu-Al | 760A | N/A | 2 openings line-side, 2 openings load-side per section |
| 16378 | Connector-Stud | 1, 2, 3 | Line: 500MCM - #6Cu-Al (2); Load: 0.25-20 x 1.0 Stud | 380A | 0.25-20 x 1.0 Stud | 2 Line openings |
| 16383 | Connector-Stud | 1, 2, 3 | Line: 500MCM - #6Cu-Al (1); Load: 0.38-16 x 1.25 Stud | 380A | 0.38-16 x 1.25 Stud | 1 Line opening |
| 16582 | Connector-Stud | 1, 2, 3 | Line: (2) 500MCM - #6Cu-Al (2); Load: 0.38-16 x 1.63 Stud | 760A | 0.38-16 x 1.63 Stud | 2 Line openings, 2 Load openings |
| 16390 | Stud-Stud | 1, 2, 3 | Line: 3/8-16 x 1-1/8; Load: 3/8-16 x 1-1/8 | 250A | 3/8-16 x 1-1/8 | N/A |
| 16394 | Stud-Stud | 1, 2, 3 | Line: 1/2-13 x 1-1/16; Load: 1/2-13 x 1-1/16 | 400A | 1/2-13 x 1-1/16 | N/A |
| 16395 | Stud-Stud | 1, 2, 3 | Line: 3/8-16 x 1-7/16; Load: (2) 1/4-20 x 1-9/16 | 310A | 3/8-16 x 1-7/16 | 2 Load openings |
| 16591 | Stud-Stud | 1, 2, 3 | Line: 3/8-16 x 1-7/16 (2); Load: 3/8-16 x 1-7/16 (2) | 400A | 3/8-16 x 1-7/16 | 2 Line openings, 2 Load openings |
|
|
EATON 16370-2 Images |